How to setup pedestrian opening?
The pedestrian configuration differs depending on the generation of motherboard integrated into your motor:
- Merak BT A motherboard,
- Other motherboards
Before starting, make sure that the gate is stopped in the closed position and your motor is powered.
1 / Configuration with a MERAK BT A motherboard
1. Check that the "pedestrian" entrance is used correctly
The control unit has two control inputs:
- Terminal 60 : common orders
- Terminal 62 = 2 ICs: Default Pedestrian Function
If you are using a wired button for pedestrian opening, connect a NO contact between 60 and 62.
2. Check the pedestrian entrance configuration in the LOGICS menu
Reminder: The entrance is already set to "pedestrian" by default, if any changes have been made previously, make sure that the 62 bollard is configured correctly.
- Go to the LOGIC menu
- Look for line 2 IC (corresponding to terminal 62)
- Select the value 4 = PED (pedestrian opening)
3. Adjust the percentage of pedestrian opening
The partial opening determines the pedestrian opening as a percentage of the total gate travel.
- Go to the settings menu .
- Select partial opening "ped opening"
- Choose a value between 10% and 100%, default the setting is 30%.
Note that the higher the value, the wider the gate will open
4. Add a remote control for the pedestrian function
If you want to trigger the pedestrian function from a remote control, you have 2 possibilities
4.1.1 Advanced Menu
- Go to the RADIO menu
- Choose "Add1ch" (add second channel key)
Press the desired button on the remote control
4.1.2 Shortcut
Press the button for 5 seconds – which allows us to access the programming menu and continue with the remote control programming procedure (see diagram above).
5. Test the function
Perform a simple test based on your configuration:
- Press the wired button; the gate should open partially.
- Press the dedicated radio button; the gate should open partially.
If the portal opens completely, check that:
- The PED message is displayed on the screen. If not, make sure that in the
- 2 CI = 4 (PED)
- The assigned radio channel is configured in CH = 4 (PED)
- If you see PED and no partial open, make sure that the "Partial open" setting is not at 100%.
2 / Configuration with a MERAK motherboard
1. Check that the "pedestrian" entrance is used correctly
The MERAK motherboard has two control inputs:
- Terminal 60 : common orders
- Terminal 62 = IC2: Default Pedestrian Function
If you are using a wired button for pedestrian opening, connect a NO contact between 60 and 62.
2. Configure the pedestrian entrance in the LOGICS menu
Reminder: The entrance is already set to "pedestrian" by default
- Go to the LOGIC menu .
- Look for line IC 2 (corresponding to terminal 62)
- Select the value 4 = PED (pedestrian opening)
- Adjust the percentage of pedestrian opening
The partial opening determines the pedestrian opening as a percentage of the total gate travel
- Go to the settings menu
- Select Partial Open.
- Choose a value between 10% and 99%, default setting is 20%
Note that the higher the value, the wider the gate will open.
3.Add a remote control for the pedestrian function
If you want to trigger the pedestrian function from a remote control:
- Go to the RADIO menu
- Choose Add Start (add second channel key)
- Press the desired button on the remote control
If no AUX 0 and AUX 3 outputs are configured as the 2nd radio channel, the 2nd channel automatically triggers the pedestrian opening.
By default the AUX 3 output is set to 0 (2nd radio channel), you have to change the programming and set it to greater than or equal to 1.
Test the pedestrian opening from your wired switch and/or remote control according to your site configuration.
3 / The HAMAL BT A control unit
1. Check that the "pedestrian" entrance is used correctly
The HAMAL motherboard has two control inputs:
- Terminal 60 : common orders
- Terminal 62 = IC2: Default Pedestrian Function
If you are using a wired button for pedestrian opening, connect a NO contact between 60 and 62.
2. Configure the pedestrian entrance via LOGICS DIP-switches
The IC2 input is already set to Pedestrian Mode (PED) in the factory setting.
As a reminder, the Configuration I/O table shows:
- DIP 2 = OFF → IC2 = PED (piéton)
- Make sure that DIP 2 is OFF to keep IC2 in pedestrian mode.
No further modifications are required for the pedestrian entrance.
3. Add a remote control for the pedestrian function
If you want to trigger the pedestrian function from a remote control:
- Press the S2 button on the card for 1 second
- Follow the sequence below of the diagram