SMARTLIGHT COMMUNICATION POINT MASTER V2

Centralyzing control panel for PGS Smartlight. Manages data collection of all connected devices (up to 96 sensors). Complete with control unit, terminals, power supply and RS485/LAN communication device.

Basic components

Cabinet with UV protection.
Halogen free materials.
Zone controller.
RS485 / LAN converter.
Converter and Zone controller power supply.
Single space sensors power supply.
Variable message sign power supply.
Clamps with dedicated communication and power lines for sensors and sign connection.

Operations

The Zone controller uses 3 Bus to supply power and collect data from sensors (Max 96, 32 sensors each Bus ).
For big areas it is possible to connect to the server more Zone controllers.
The Zone controller centralizes data to be transmitted to the Server; receive from the server the status of all devices; transmit information to the variable message indication panels.
The Zone controller collect also data for counters

Versions

CodeKansainv. koodiTitleCommunicationPower consumption (zone controller)Supply voltagePower consumption (96 sensors)Operating temperaturePower consumption (panels)SizesSuojausluokka
P208006M22613203 SMARTLIGHT COMMUNICATION POINT MASTER V2

Tekniset tiedotteet

tekninen piirustus
Suojausluokka IP66 - IK10
Communication interface RS485 – TCP/IP
Operating temperature 0 ÷ 50 °C
Supply voltage 230 VAC ± 10%

Tarvitsetko lisätietoja?