LEO B CBB SV 18D

Product code I700125 10001

Built-in control panel for 1 x 230V operator for sliding gates Application: built-in control unit for one 230V operator for sliding gates Card power supply: 230 V single-phase Operator power supply: 230V 750W Main features: removable terminal blocks with new standard colour-coding, simplified scenario-based programming with display, incorporated dual channel receiver, D-Track anti-crushing system, slowdown during opening and closing Main functions: automatic re-closing, fast closing, pedestrian opening

Maximum output 750 W
Board power supply 220-230 V
Programming Display
Power supply accessories 24V - 1A
Light sensor 1
Safety edge 1
Resistive edge 1
Tested photocell 1
Tested safety edge 1
Stop 1
Start 1
Traffic light control 1
Open 1
Close 1
Pedestrian open 1
Open with timer 1
Pedestrian open with timer 1
Blinker 1
Configurable AUX 3 24V - 0,5A
Interconnectivity no
Configurable AUX 1 0
Configurable AUX 1 0
Configurable AUX 2 0
Configurable AUX 2 0
Solenoid Lock 1
Solenoid Lock 1
Alarm 1
Alarm 1
Courtesy Light 1
Courtesy Light 1
Gate open warning light 1
Gate open warning light 1
Courtesy light 1
Courtesy light 1
Gate open alarm 1
Gate open alarm 1
Electric release lock 1
Electric release lock 1
Flashing + Maintenance 1
Flashing + Maintenance 1
Maintenance 1
Maintenance 1
Electric magnetic lock 1
Electric magnetic lock 1
Bistable radio channel 1
Bistable radio channel 1
Zone light 1
Zone light 1
Gate status 1
Gate status 1
Tamper-proof 1
Tamper-proof 1
Time delay radio channel 1
Time delay radio channel 1
Stairs light 1
Stairs light 1
Obstacle detection (hydraulic only) 0
Obstacle detection (hydraulic only) 0
Bar open 0
Bar open 0
Stop contact activated 0
Stop contact activated 0
Pre-flashing 0
Pre-flashing 0
Bar lock 0
Bar lock 0
Open contact activated 0
Open contact activated 0
Close contact activated 0
Close contact activated 0
PDM contact activated 0
PDM contact activated 0
Start contact activated 0
Start contact activated 0
FRAC contact 0
FRAC contact 0
Encoder response 0
Encoder response 0
Photocell response 0
Photocell response 0
Contact according to radio channel 0
Contact according to radio channel 0
UPS contact 0
UPS contact 0
bollard lowered 0
bollard lowered 0
Black out 0
Black out 0
ECD pressure switch not functioning 0
ECD pressure switch not functioning 0
Alarm 0
Alarm 0
Bar closed 0
Bar closed 0
FCC sensor not functioning 0
FCC sensor not functioning 0
Buzzer 0
Buzzer 0
bollard raised 0
bollard raised 0

An unexpected error occurred: please reload the page or try again later.